Water Bath Heater
- Max Mud Return Flow up to 3500 GPM
- Fast Gas busting technology
- Design Duty to 15 barg (Min)
- Pressure Rating (minimum): Full Vacuum
- Pressure Rating Operating: 0.4 to 85 barg
- Minimum Design Temperature: -20 ºC
- Maximum Design Temperature: 75 ºC
- Mud Density from 1900-2200Kg /m3
- Gas Processing Rate 1,400- 2,500 ft3/min
- Area Classification Zone 1 ATEX CE Marked
Certification
Specifications
Kapwell Water Bath Heater is design, manufactured and tested to the requirements below;
- ABS- Rules for Building and Classing Mobile Offshore Units 2021
- API Spec 12J Specification for Oil and Gas Separators, Eighth Edition
- NACE Standard MR-01-75/ISO15156 (latest revision)
- ASME Boiler and Pressure Vessel Code, Section VIII, Division I (latest revision)
- All welding on the vessel shall meet ASME requirements
- ASME VIII Div. 1 UG-99
Description
The Water Bath Heater forms part of the well control system and plays a critical part in ensuring the safe operation of the rig. The Water Bath Heater is located on or in the vicinity of the drill floor, downstream of the buffer block on the choke and kill manifold. Employed as a safety-critical piece of Well Control Equipment the MGS is used in series with the choke manifold to safely circulate out a gas kick from the well.
The Water Bath Heater handles a high proportion of mud solids and may experience hydrate plugging as a result of gas expansion through the choke. The liquid seal ensures that separated gas vents safely without breaking through to the mud tanks. The design of our Mud Gas Separator is based on conventional process practice and has adopted the latest notices and publications.
If the drilling rig requires a compact solution, Kapwell can offer a trip tank based liquid seal, where the trip tank is used as a liquid seal, or alternatively, the seal may be in the form of an external U-tube. We can supply either vertical or horizontal MGS, both of which are fitted with internal baffles and distribution nozzles but the performance of the liquid seal is dependent on the chosen design features.
The capacity of the Water Bath Heater is dependent on the design. If the capacity is exceeded, liquid mud or oil droplets may be carried up through the vent line. More importantly, gas may blow straight through the U-tube (Liquid Seal) and into the shale-shaker house, where there may be potential for explosion and fire. It is essential to verify that the system is capable of handling the maximum amount of fluid and gas that could be produced by the well in the case of a severe kick.
Our technology offers the highest level of safety during mud and gas processing.
Kapwell certified Mud Gas Separator can handle a high proportion of mud solids and may experience hydrate plugging as a result of gas expansion through the choke. The liquid seal ensures that separated gas vents safely without breaking through to the mud tanks. The design of our Mud Gas Separator is based on client specification or ABS CDS requirement or conventional process practice and latest notices and publications.
You are in safe hands!
Today’s market calls for cost-effective equipment with high reliability. Our equipment is cost-effective yet high quality designed by an expert in the industry.
Engineering Services
NEXT STEPS...
From arctic conditions, desserts, remote locations to harsh offshore facilities and aggressive desert environments, Kapwell provides world-class products and services. For more information contact our sales representative.